Fill out the form with your specific items – don’t hesitate to list even unique or hard-to-find components – submit your inquiry, and get the precisely tailored solutions you’re looking for! Forget generic offerings; we specialize in understanding your exact needs and delivering results that fit like a glove

Ex d Double Seal Cable Gland for Armoured Cable, IIC Gb

The Triple-Function Solution

Terminating armored cables requires a solution that provides more than just an environmental seal. Our armored cable glands are engineered to perform three critical functions simultaneously, ensuring a safe, reliable, and long-lasting connection.

Secure Mechanical Armor Lock & Retention

360° Electrical Grounding Continuity

IP66/IP68 Double Seal on Inner & Outer Sheath

Robust Brass or Stainless Steel Construction

How to Choose the Right Armored Gland

Selecting the correct gland depends on your application’s environment. Use this guide to identify the right product series for your needs.

For General Industrial Applications

For use in non-hazardous locations where mechanical protection and environmental sealing are required.

  • Indoor / Dry Locations: Choose our BW Series for basic armor clamping and earth continuity (IP30).
  • Outdoor / Wet Locations: Choose our CW Series for weatherproof sealing on the outer sheath (IP66/67).

For Hazardous Locations (ATEX/IECEx)

For use in Zone 1, 2, 21, & 22 where certified explosion-proof protection is mandatory.

  • Single Seal (Ex-V / Ex-VIIIG): Provides armor clamping and a robust outer environmental seal. Ideal for most applications.
  • Double Seal (Ex-VIIG): Offers maximum protection with an additional flameproof seal on the cable’s inner sheath.

Find and Specify Your Armored Gland Model

Find the correct gland for your armored cable. Select by application, seal type, and cable dimensions for a perfect fit.

BW Indoor Armoured - Standard Indoor - Metric & NPT Thread
Thread Thread size
METRIC
Thread size
NPT
Minimum length of thread Cable Range Min (mm) Cable Range Max (mm)
BW20SM201/2″1011.515.5
BW20LM201/2″101420.5
BW25SM253/4″101824
BW25LM253/4″102027
BW32SM321″1026.333.5
BW32LM321″1026.333.5
BW40SM401-1/4″1331.539.5
BW40LM401-1/4″133240
BW50SM501-1/2″1338.246.3
BW50LM502″134452.6
BW63SM632″1450.159
BW63LM632-1/2″145665.3
BW75SM752-1/2″156271.6
BW75LM753″156878
BW90M903″2080.591
CW Series Cable Glands - Conduit Thread
Thread Thread size Minimum length of thread Cable Range Min (mm) Cable Range Max (mm)
CW20S201011.817.8
CW20L201014.020.8
CW25S251018.024.0
CW25L251020.327.4
CW32S321024.531.0
CW32L321026.534.2
CW40S401330.438.5
CW40L401333.241.0
CW50S501340.047
CW50L501344.053.5
CW63S631450.059.0
CW63L6313.556.066.0
CW75S751563.573.0
CW75L751569.073.0
Ex-VII Series Cable Glands - Metric/NPT/G Thread
Thread Type Product Number Locking Range
(mm)
Max. Outlet
(mm)
Thread Length
GL (mm)
Spanner Size
(mm)
M16 × 1.5Ex-VIIM165-16101524
M20 × 1.5Ex-VIIM205-16101524
M20 × 1.5DEx-VIIM20D5-20151530
M25 × 1.5Ex-VIIM255-20151530
M25 × 1.5DEx-VIIM25D8-26201538
M32 × 1.5Ex-VIIM328-26201738
M32 × 1.5DEx-VIIM32D15-33261745
M40 × 1.5Ex-VIIM40-3315-33261745
M40 × 1.5DEx-VIIM40D16-40331755
M50 × 1.5Ex-VIIM5016-40332055
M50 × 1.5DEx-VIIM50D18-50412068
M63 × 1.5Ex-VIIM6318-50412068
M63 × 1.5DEx-VIIM63D25-64532082
M75 × 2Ex-VIIM7525-64532282
M88 × 2Ex-VIIM8831-80752298
M100 × 2Ex-VIIM10040-968322110
M115 × 2Ex-VIIM11540-1039022125
M130 × 2Ex-VIIM13098-11910022140
NPT 3/8Ex-VIINPT3/85-16101524
NPT 1/2Ex-VIINPT1/25-16101524
NPT 1/2DEx-VIINPT1/2D5-20151530
NPT 3/4Ex-VIINPT3/45-20151530
NPT 3/4DEx-VIINPT3/4D8-26201538
NPT 1Ex-VIINPT18-26201738
NPT 1DEx-VIINPT1D15-33261745
NPT 1-1/4Ex-VIINPT1-1/415-33261745
NPT 1-1/4DEx-VIINPT1-1/4D16-40331755
NPT 1-1/2Ex-VIINPT1-1/216-40332055
NPT 1-1/2DEx-VIINPT1-1/2D18-50412068
NPT 2Ex-VIINPT218-50412068
NPT 2DEx-VIINPT2D25-64532082
NPT 2-1/2Ex-VIINPT2-1/225-64532282
NPT 3Ex-VIINPT331-80752298
NPT 4Ex-VIINPT440-1039022125
G 3/8Ex-VIIG3/85-16101524
G 1/2Ex-VIIG1/25-16101524
G 1/2DEx-VIIG1/2D5-20151530
G 3/4Ex-VIIG3/45-20151530
G 3/4DEx-VIIG3/4D8-26201538
G 1Ex-VIIG18-26201738
G 1DEx-VIIG1D15-33261745
G 1-1/4Ex-VIIG1-1/415-33261745
G 1-1/4DEx-VIIG1-1/4D16-40331755
G 1-1/2Ex-VIIG1-1/216-40332055
G 1-1/2DEx-VIIG1-1/2D18-50412068
G 2Ex-VIIG218-50412068
G 2DEx-VIIG2D25-64532082
G 2-1/2Ex-VIIG2-1/225-64532282
G 3Ex-VIIG331-80752298
G 4Ex-VIIG440-1039022125
Ex-V Series Cable Glands - Metric/NPT/G Thread
Thread
(M)
Metric Series
Code
Thread
(NPT/G)
NPT Series
Code
G Series
Code
Cable range H
(mm)
L
(mm)
Hexagonal size
Thread Thread Thread B
(mm)
A
(mm)
Across
flats
Across
corners
M16*1.5 Ex-V08-M16 3/8″ Ex-V08-NPT3/8 Ex-V08-G3/8 5-8 3-6 30 12 24 28
Ex-V10-M16 Ex-V10-NPT3/8 Ex-V10-G3/8 6-10 4-8 30 12 24 28
M20*1.5 Ex-V14-M20 1/2″ Ex-V14-NPT1/2 Ex-V14-G1/2 9-14 6-11 30 12 24 28
Ex-V16-M20 Ex-V16-NPT1/2 Ex-V16-G1/2 10-16 7-12 30 12 24 28
Ex-V18-M20 Ex-V18-NPT1/2 Ex-V18-G1/2 13-18 9-14 32 12 30 35
M25*1.5 Ex-V21-M25 3/4″ Ex-V21-NPT3/4 Ex-V21-G3/4 15-21 11-17 35 13 36 42
Ex-V24-M25 Ex-V24-NPT3/4 Ex-V24-G3/4 17-24 13-20 35 13 40 47
M32*1.5 Ex-V28-M32 1″ Ex-V28-NPT1 Ex-V28-G1 20-28 16-23 39 15 46 53
Ex-VK2-M32 Ex-V32-NPT1 Ex-V32-G1 23-32 18-26 39 15 46 53
M40*1.5 Ex-V35-M40 1-1/4″ Ex-V35-NPT1-1/4 Ex-V35-G1-1/4 26-35 21-29 43 15 55 64
Ex-V38-M40 Ex-V38-NPT1-1/4 Ex-V38-G1-1/4 31-38 25-32 43 15 55 64
M50*1.5 Ex-V41-M50 1-1/2″ Ex-V41-NPT1-1/2 Ex-V41-G1-1/2 34-41 28-35 48 15 65 75
Ex-V44-M50 Ex-V44-NPT1-1/2 Ex-V44-G1-1/2 37-44 31-38 48 15 65 75
M63*1.5 Ex-V50-M63 2″ Ex-V50-NPT2 Ex-V50-G2 40-50 33-43 53 16 80 92
Ex-V55-M63 Ex-V55-NPT2 Ex-V55-G2 43-55 36-47 53 16 80 92
M75*1.5 Ex-V63-M75 2-1/2″ Ex-V63-NPT2-1/2 Ex-V63-G2 50-63 42-53 58 16 96 111
Ex-V68-M75 Ex-V68-NPT2-1/2 Ex-V68-G2-1/2 54-68 45-58 58 16 96 111
M88*2 Ex-V72-M88 3″ Ex-V72-NPT3 Ex-V72-G3 62-72 52-62 64 18 114 134
Ex-V79-M88 Ex-V79-NPT3 Ex-V79-G3 67-79 56-67 64 18 114 134
M110*2 Ex-V89-M110 4″ Ex-V89-NPT4 Ex-V89-G4 78-89 65-75 70 18 128 148
Ex-V105-M110 Ex-V105-NPT4 Ex-V105-G4 88-104.5 74-91 70 18 138 148
Ex-VIIG Series Cable Glands - Metric/NPT/G Thread
Thread Type Product Number Locking Range
(mm)
Max. Outlet
(mm)
Thread Length
GL (mm)
Spanner Size
(mm)
M16 × 1.5Ex-VIIGM165-16101524
M20 × 1.5Ex-VIIGM205-16101524
M20 × 1.5DEx-VIIGM20D5-20151530
M25 × 1.5Ex-VIIGM255-20151530
M25 × 1.5DEx-VIIGM25D8-26201538
M32 × 1.5Ex-VIIGM328-26201738
M32 × 1.5DEx-VIIGM32D15-33261745
M40 × 1.5Ex-VIIGM40-3315-33261745
M40 × 1.5DEx-VIIGM40D16-40331755
M50 × 1.5Ex-VIIGM5016-40332055
M50 × 1.5DEx-VIIGM50D18-50412068
M63 × 1.5Ex-VIIGM6318-50412068
M63 × 1.5DEx-VIIGM63D25-64532082
M75 × 2Ex-VIIGM7525-64532282
M88 × 2Ex-VIIGM8831-80752298
M100 × 2Ex-VIIGM10040-968322110
M115 × 2Ex-VIIGM11540-1039022125
M130 × 2Ex-VIIGM13098-11910022140
NPT 3/8Ex-VIIGNPT3/85-16101524
NPT 1/2Ex-VIIGNPT1/25-16101524
NPT 1/2DEx-VIIGNPT1/2D5-20151530
NPT 3/4Ex-VIIGNPT3/45-20151530
NPT 3/4DEx-VIIGNPT3/4D8-26201538
NPT 1Ex-VIIGNPT18-26201738
NPT 1DEx-VIIGNPT1D15-33261745
NPT 1-1/4Ex-VIIGNPT1-1/415-33261745
NPT 1-1/4DEx-VIIGNPT1-1/4D16-40331755
NPT 1-1/2Ex-VIIGNPT1-1/216-40332055
NPT 1-1/2DEx-VIIGNPT1-1/2D18-50412068
NPT 2Ex-VIIGNPT218-50412068
NPT 2DEx-VIIGNPT2D25-64532082
NPT 2-1/2Ex-VIIGNPT2-1/225-64532282
NPT 3Ex-VIIGNPT331-80752298
NPT 4Ex-VIIGNPT440-1039022125
G 3/8Ex-VIIGG3/85-16101524
G 1/2Ex-VIIGG1/25-16101524
G 1/2DEx-VIIGG1/2D5-20151530
G 3/4Ex-VIIGG3/45-20151530
G 3/4DEx-VIIGG3/4D8-26201538
G 1Ex-VIIGG18-26201738
G 1DEx-VIIGG1D15-33261745
G 1-1/4Ex-VIIGG1-1/415-33261745
G 1-1/4DEx-VIIGG1-1/4D16-40331755
G 1-1/2Ex-VIIGG1-1/216-40332055
G 1-1/2DEx-VIIGG1-1/2D18-50412068
G 2Ex-VIIGG218-50412068
G 2DEx-VIIGG2D25-64532082
G 2-1/2Ex-VIIGG2-1/225-64532282
G 3Ex-VIIGG331-80752298
G 4Ex-VIIGG440-1039022125
Ex-VIIIG Series Cable Glands - Metric/NPT/G Thread
Thread Type Product Number Locking Range
(mm)
Max. Outlet
(mm)
Thread Length
GL (mm)
Spanner Size
(mm)
M16 × 1.5Ex-VIIIGM165-16101524
M20 × 1.5Ex-VIIIGM205-16101524
M20 × 1.5DEx-VIIIGM20D5-20151530
M25 × 1.5Ex-VIIIGM255-20151530
M25 × 1.5DEx-VIIIGM25D8-26201538
M32 × 1.5Ex-VIIIGM328-26201738
M32 × 1.5DEx-VIIIGM32D15-33261745
M40 × 1.5Ex-VIIIGM40-3315-33261745
M40 × 1.5DEx-VIIIGM40D16-40331755
M50 × 1.5Ex-VIIIGM5016-40332055
M50 × 1.5DEx-VIIIGM50D18-50412068
M63 × 1.5Ex-VIIIGM6318-50412068
M63 × 1.5DEx-VIIIGM63D25-64532082
M75 × 2Ex-VIIIGM7525-64532282
M88 × 2Ex-VIIIGM8831-80752298
M100 × 2Ex-VIIIGM10040-968322110
M115 × 2Ex-VIIIGM11540-1039022125
M130 × 2Ex-VIIIGM13098-11910022140
NPT 3/8Ex-VIIIGNPT3/85-16101524
NPT 1/2Ex-VIIIGNPT1/25-16101524
NPT 1/2DEx-VIIIGNPT1/2D5-20151530
NPT 3/4Ex-VIIIGNPT3/45-20151530
NPT 3/4DEx-VIIIGNPT3/4D8-26201538
NPT 1Ex-VIIIGNPT18-26201738
NPT 1DEx-VIIIGNPT1D15-33261745
NPT 1-1/4Ex-VIIIGNPT1-1/415-33261745
NPT 1-1/4DEx-VIIIGNPT1-1/4D16-40331755
NPT 1-1/2Ex-VIIIGNPT1-1/216-40332055
NPT 1-1/2DEx-VIIIGNPT1-1/2D18-50412068
NPT 2Ex-VIIIGNPT218-50412068
NPT 2DEx-VIIIGNPT2D25-64532082
NPT 2-1/2Ex-VIIIGNPT2-1/225-64532282
NPT 3Ex-VIIIGNPT331-80752298
NPT 4Ex-VIIIGNPT440-1039022125
G 3/8Ex-VIIIGG3/85-16101524
G 1/2Ex-VIIIGG1/25-16101524
G 1/2DEx-VIIIGG1/2D5-20151530
G 3/4Ex-VIIIGG3/45-20151530
G 3/4DEx-VIIIGG3/4D8-26201538
G 1Ex-VIIIGG18-26201738
G 1DEx-VIIIGG1D15-33261745
G 1-1/4Ex-VIIIGG1-1/415-33261745
G 1-1/4DEx-VIIIGG1-1/4D16-40331755
G 1-1/2Ex-VIIIGG1-1/216-40332055
G 1-1/2DEx-VIIIGG1-1/2D18-50412068
G 2Ex-VIIIGG218-50412068
G 2DEx-VIIIGG2D25-64532082
G 2-1/2Ex-VIIIGG2-1/225-64532282
G 3Ex-VIIIGG331-80752298
G 4Ex-VIIIGG440-1039022125

Answering Your Key Questions

BW glands are for indoor, dry environments only. They provide mechanical retention and earth continuity for the armor but offer no environmental seal (IP30). CW glands are for outdoor or wet environments, as they include a seal on the cable’s outer sheath to provide weatherproof protection (IP66/67).

single seal Ex gland is suitable for most hazardous area applications. A double seal gland provides a higher level of safety by creating a flameproof seal on the cable’s inner bedding, in addition to the outer seal. This is often specified for the most critical applications, areas with high-pressure gas, or where project specifications demand maximum protection against flame propagation.

You need key measurements from your cable’s datasheet. For a CW or single seal Ex gland, you need the overall diameter and the armor wire diameter. For a double seal Ex gland, you need the overall diameter, the inner bedding diameter, and the armor wire diameter. Match these to the ranges in our product tables for a secure, compliant termination.

Ensure a Safe and Secure Connection for Your Armored Cables

Don’t risk connection failure. Our industrial armored cable glands provide the robust termination required for demanding environments. Contact our team for sizing assistance and quotes.

Bepto Logo