A2 타입 황동 케이블 글랜드의 구성에 대해 자세히 알아보기

A2 타입 황동 케이블 글랜드의 구성에 대해 자세히 알아보기

Understanding the intricate construction of A2 type brass cable glands is crucial for engineers and procurement managers who need reliable cable termination solutions. Many professionals struggle with selecting the right cable gland specifications without fully understanding the internal construction and how each component contributes to overall performance.

A2 타입 황동 케이블 글랜드는 미터 나사산, 압축 밀봉 시스템, 스트레인 릴리프 메커니즘, 통합 접지 연속성 등 견고한 다중 구성 요소 구조를 갖추고 있으며, IP68 환경 보호 및 기계적 내구성을 갖춘 외장 케이블 종단을 위해 특별히 설계되어 장기간 신뢰성이 필요한 산업 분야에서 사용할 수 있습니다.

Just last month, Robert, a project engineer from a manufacturing facility in Birmingham, UK, contacted me after experiencing seal failures with inferior cable glands. His team needed to understand the precise construction differences between A2 type brass glands and standard versions to prevent costly equipment downtime in their automated production lines 😉

목차

What Makes A2 Type Brass Cable Glands Unique?

The A2 designation represents a specific construction standard that differentiates these cable glands from other types in terms of design philosophy and application focus.

A2 type brass cable glands are specifically engineered for armored cable termination with enhanced mechanical strength, featuring a specialized construction that includes armor clamping mechanisms, extended thread engagement, reinforced body design, and superior earthing continuity1 compared to standard cable glands, making them ideal for heavy-duty industrial applications.

Design Philosophy and Standards

A2 Construction Standards:

  • Enhanced mechanical strength requirements
  • Specialized armored cable accommodation
  • Extended service life specifications
  • Superior environmental protection ratings
  • Integrated earthing and bonding capabilities

Key Differentiating Features:

  • Reinforced body wall thickness (minimum 2.5mm)
  • 확장된 스레드 결합 길이
  • Specialized armor clamping system
  • Enhanced sealing performance
  • 우수한 내식성

Construction Specifications

구성 요소A2 Type Specification표준 유형
Body Wall Thickness2.5-4.0mm1.5-2.5mm
스레드 참여8-12 threads minimum5-8 threads
Sealing RingsDual compression systemSingle seal
아머 클램프Integrated designOptional/separate
재료 등급CW617N/CW614N2CW617N standard
IP 등급IP68 guaranteedIP65-IP67 typical

Application-Specific Design Elements

Armored Cable Optimization:

  • Specialized armor wire accommodation
  • Integrated armor clamping mechanism
  • Enhanced strain relief design
  • Superior earthing continuity
  • Mechanical protection features

Industrial Environment Adaptation:

  • Vibration resistance construction
  • Temperature cycling durability
  • 내화학성 속성
  • UV stability for outdoor use
  • 기계적 내충격성

성능 이점

Enhanced Reliability:

  • 25+ year service life expectation
  • Superior environmental sealing
  • 유지 관리 요구 사항 감소
  • Consistent performance under stress
  • 예측 가능한 장애 모드

운영상의 이점:

  • Simplified installation procedures
  • Reduced inventory complexity
  • 총 소유 비용 절감
  • 시스템 안정성 향상
  • Enhanced safety performance

At Bepto, our A2 type brass cable glands undergo rigorous quality control processes in our CNC machining facilities. We maintain strict dimensional tolerances and material specifications to ensure consistent performance across all production batches.

How Are the Key Components Constructed?

Each component of an A2 type brass cable gland serves a specific function and requires precise manufacturing to achieve optimal performance.

A2 type brass cable glands consist of seven primary components: the main body with metric threads, compression nut, sealing washers, compression cone, armor clamp ring, earthing tag, and strain relief boot, each manufactured to precise tolerances using specialized machining processes and quality-controlled brass alloys for maximum durability and performance.

SWA용 방폭 CW 케이블 글랜드, IP67IP66
Explosion Proof CW Cable Gland for SWA, IP67 IP66

Main Body Construction

Body Design Features:

  • CNC-machined from solid brass bar stock
  • Metric thread specification (M12-M75 range)
  • Integrated sealing surfaces with precise finish
  • Internal cable accommodation chamber
  • Armor wire termination area

제조 프로세스:

  • Computer-controlled turning operations
  • Thread rolling for superior strength
  • Surface finishing to Ra 1.6 specification
  • Dimensional inspection at multiple stages
  • Final assembly preparation

Compression System Components

Compression Nut Design:

  • Hexagonal external profile for tool engagement
  • Internal compression thread system
  • Integrated sealing surface preparation
  • Torque specification optimization
  • Anti-seizing surface treatment

Sealing Washer Construction:

  • EPDM rubber compound selection
  • Shore A hardness 70±5 specification
  • Temperature range -40°C to +125°C
  • 내화학성 속성
  • 압축 설정 저항

Armor Clamping Mechanism

Armor Clamp Ring Features:

  • Serrated internal surface for wire grip
  • Tapered design for compression action
  • Corrosion-resistant surface treatment
  • Precise dimensional control
  • Integration with earthing system

Earthing Tag Construction:

  • Brass or stainless steel material
  • M4 or M5 earthing screw provision
  • Low-resistance electrical path
  • Corrosion protection coating
  • Mechanical strength verification

Strain Relief System

Boot Design Elements:

  • Flexible elastomer material selection
  • Graduated flexibility zones
  • Cable diameter accommodation range
  • Environmental protection properties
  • Long-term durability characteristics

성능 사양:

  • Bend radius protection: 6x cable diameter
  • Temperature stability: -40°C to +100°C
  • UV resistance for outdoor applications
  • Oil and chemical resistance
  • Fatigue resistance testing

품질 관리 조치

구성 요소 검사:

  • Dimensional verification using CMM
  • 재료 구성 분석
  • 표면 마감 측정
  • Thread gauge verification
  • Assembly fit testing

성능 검증:

  • Torque testing for proper assembly
  • Sealing performance verification
  • 전기적 연속성 테스트
  • Environmental exposure testing
  • Long-term durability assessment

Ahmed, who manages electrical installations for a petrochemical facility in Dubai, UAE, required detailed component specifications for his ATEX Zone 1 applications. Our engineering team provided comprehensive construction drawings and material certificates, enabling his team to achieve full regulatory compliance with superior long-term performance.

What Materials and Manufacturing Processes Are Used?

The selection of materials and manufacturing processes directly impacts the performance, durability, and cost-effectiveness of A2 type brass cable glands.

A2 type brass cable glands utilize CW617N or CW614N brass alloys for the main body, providing excellent corrosion resistance and machinability, with EPDM sealing materials, stainless steel hardware, and specialized surface treatments, manufactured using precision CNC machining, thread rolling3, and automated assembly processes to ensure consistent quality and performance.

Primary Material Selection

Brass Alloy Specifications:

  • CW617N (58% copper, 39% zinc, 2% lead)
  • CW614N (58% copper, 39% zinc, 3% lead)
  • Excellent corrosion resistance properties
  • Superior machinability characteristics
  • Optimal strength-to-weight ratio

머티리얼 속성:

  • Tensile strength: 380-420 MPa
  • Yield strength: 140-180 MPa
  • Elongation: 15-25%
  • Hardness: 80-120 HB
  • Electrical conductivity: 26-28% IACS

Sealing Material Technology

EPDM Rubber Characteristics:

  • Ethylene Propylene Diene Monomer base
  • Shore A hardness 70±5
  • Temperature range: -40°C to +125°C
  • Excellent ozone resistance
  • Superior weathering properties

Alternative Sealing Materials:

  • NBR for oil resistance applications
  • Viton for chemical resistance
  • Silicone for extreme temperatures
  • TPE for food-grade applications
  • Custom compounds for specific needs

Manufacturing Process Overview

CNC Machining Operations:

  • Computer-controlled turning centers
  • Multi-axis machining capabilities
  • Automated tool changing systems
  • Real-time dimensional monitoring
  • 통계적 프로세스 제어

Thread Manufacturing:

  • Thread rolling for superior strength
  • Precise pitch and profile control
  • 표면 마감 최적화
  • 치수 정확도 검증
  • Thread gauge inspection

Surface Treatment Processes

부식 방지:

  • Nickel plating for enhanced durability
  • Chromium plating for wear resistance
  • 패시베이션 처리
  • Organic coating systems
  • Specialized marine coatings

Quality Enhancement:

  • Surface roughness control
  • Dimensional stability improvement
  • Appearance standardization
  • 성능 최적화
  • 장기적인 내구성

Quality Assurance Systems

재료 인증:

  • Mill test certificates for all materials
  • Chemical composition verification
  • Mechanical property testing
  • 추적성 문서
  • 공급업체 자격 프로그램

프로세스 제어:

  • Statistical process monitoring
  • Automated inspection systems
  • 지속적인 개선 프로그램
  • 시정 조치 절차
  • 고객 피드백 통합

At Bepto, we maintain strict material traceability from raw material receipt through final product delivery. Our ISO9001 and IATF16949 certifications ensure consistent quality and continuous improvement in our manufacturing processes.

How Does the Sealing System Work?

The sealing system is the most critical aspect of A2 type brass cable gland construction, determining environmental protection and long-term reliability.

A2 type brass cable glands employ a dual-compression sealing system featuring primary cable sealing through radial compression of EPDM washers against the cable jacket, and secondary environmental sealing via thread-mounted O-rings, creating IP68 protection through controlled compression forces that maintain seal integrity across temperature variations and mechanical stress.

Primary Sealing Mechanism

Cable Jacket Sealing:

  • Radial compression against cable outer jacket
  • 둘레에 균일한 압력 분포
  • Accommodation of cable diameter variations
  • Compensation for thermal expansion/contraction
  • Long-term seal integrity maintenance

Compression Force Control:

  • Calculated compression ratios for optimal sealing
  • Torque specifications for consistent results
  • Over-compression prevention mechanisms
  • Under-compression indication systems
  • Field verification procedures

Secondary Environmental Sealing

Thread Sealing System:

  • O-ring seals in thread engagement area
  • Protection against ingress through threads
  • Redundant sealing for critical applications
  • Maintenance accessibility features
  • 장기적인 성능 안정성

Sealing Performance Characteristics:

  • IP68 rating verification testing
  • Pressure resistance up to 10 bar
  • 온도 사이클링 성능
  • 내화학성 속성
  • UV degradation resistance

Sealing Material Performance

EPDM Sealing Properties:

  • 뛰어난 압축 세트 저항
  • Wide temperature operating range
  • Superior ozone and weather resistance
  • Chemical compatibility with most cables
  • Long-term aging characteristics

성능 테스트:

  • Accelerated aging tests at elevated temperatures
  • Compression set testing per ASTM D395
  • 내화학성 평가
  • UV exposure testing
  • Thermal cycling verification

Installation Critical Factors

Proper Assembly Techniques:

  • 케이블 준비 요구 사항
  • Sealing washer positioning
  • Compression nut torque specifications
  • 육안 검사 기준
  • Performance verification methods

일반적인 설치 오류:

  • Insufficient cable preparation
  • Incorrect sealing washer orientation
  • Over-tightening causing seal damage
  • 조립 중 오염
  • Inadequate performance verification

Maintenance and Service Life

Seal Inspection Requirements:

  • Visual inspection for damage or degradation
  • Torque verification procedures
  • Performance testing methods
  • 교체 기준 및 절차
  • 문서 요구 사항

Expected Service Life:

  • 20+ years under normal conditions
  • 15+ years in harsh environments
  • 10+ years in extreme chemical exposure
  • Temperature cycling impact assessment
  • Predictive maintenance indicators

The sealing system design has been validated through extensive testing at our facilities, including 1000-hour salt spray exposure, thermal cycling from -40°C to +125°C, and long-term compression set testing to ensure reliable performance throughout the product lifecycle.

What Are the Quality Standards and Testing Requirements?

A2 type brass cable glands must meet stringent quality standards and undergo comprehensive testing to ensure reliable performance in demanding applications.

A2 type brass cable glands must comply with IEC 62444, IP68 environmental protection standards, ATEX directive requirements for hazardous areas, and various national standards including BS, DIN, and ANSI specifications, with mandatory testing including ingress protection verification, mechanical strength testing, corrosion resistance evaluation, and electrical continuity measurement to ensure consistent quality and performance.

국제 표준 준수

Primary Standards:

  • IEC 62444: 전기 설비용 케이블 글랜드
  • IEC 60529: IP protection degree classification
  • IEC 60079: Explosive atmospheres equipment
  • ISO 9001: Quality management systems
  • IATF 16949: Automotive quality standards

Regional Standards:

  • BS EN 50262: European cable gland standards
  • DIN VDE 0619: German electrical installation standards
  • ANSI/UL 514B: North American conduit fittings
  • JIS C 8480: Japanese electrical equipment standards
  • GB/T 5095: Chinese connector standards

Mandatory Testing Procedures

Environmental Protection Testing:

  • IP68 ingress protection verification
  • Continuous immersion testing (1m depth, 24 hours)
  • Dust ingress prevention testing
  • 온도 사이클링 성능
  • 내습성 평가

Mechanical Performance Testing:

  • Tensile strength testing (minimum 500N)
  • Torque resistance verification
  • 내충격성 테스트
  • Vibration endurance testing
  • Fatigue cycle testing

Material Quality Verification

Chemical Composition Analysis:

  • Spectroscopic analysis of brass alloys
  • Lead content verification for RoHS compliance
  • Trace element identification
  • Material certification documentation
  • Supplier qualification verification

기계적 특성 테스트:

  • Tensile strength measurement
  • 항복 강도 결정
  • Elongation percentage testing
  • Hardness verification (Brinell/Vickers)
  • Impact resistance evaluation

전기 성능 표준

연속성 테스트 요구 사항:

  • Earth continuity resistance measurement
  • Contact resistance verification
  • 절연 저항 테스트
  • Dielectric strength testing
  • EMC shielding effectiveness

성능 사양:

  • Earth continuity: <0.1 ohm maximum
  • Insulation resistance: >100 MΩ minimum
  • Dielectric strength: 2000V AC minimum
  • Shielding effectiveness: >60dB typical
  • Temperature coefficient stability

품질 관리 절차

수신 자료 검사:

  • Material certification verification
  • Dimensional inspection sampling
  • 표면 마감 측정
  • Chemical composition spot checking
  • Supplier performance monitoring

생산 품질 관리:

  • 통계적 프로세스 제어 구현
  • Real-time dimensional monitoring
  • Assembly torque verification
  • Functional testing procedures
  • Final inspection protocols

Certification and Documentation

필수 인증:

  • 유럽 규정 준수를 위한 CE 마크
  • 방폭 지역용 ATEX 인증
  • UL listing for North American markets
  • CSA certification for Canadian applications
  • IECEX certification for international use

문서 요구 사항:

  • 자재 추적성 기록
  • Test certificates and reports
  • 설치 및 유지 관리 지침
  • Performance specification sheets
  • Warranty and service information

Third-Party Verification

Independent Testing:

  • Accredited laboratory testing
  • Witness testing procedures
  • Certification body audits
  • 성능 검증 테스트
  • Compliance assessment procedures

지속적인 모니터링:

  • Annual surveillance audits
  • Random sample testing
  • Customer feedback analysis
  • 현장 성능 모니터링
  • Corrective action implementation

At Bepto, we maintain comprehensive quality records for all A2 type brass cable glands, with full traceability from raw materials through final delivery. Our quality management system ensures consistent compliance with all applicable standards and customer requirements.

결론

A2 type brass cable glands represent sophisticated engineering solutions combining robust construction, premium materials, and precision manufacturing. Understanding their detailed construction enables informed selection decisions and optimal application performance. The multi-component design, specialized sealing systems, and rigorous quality standards ensure reliable service in demanding industrial environments.

The key to successful implementation lies in understanding how each construction element contributes to overall performance. From the CNC-machined brass body to the dual-compression sealing system, every component is engineered for long-term reliability and environmental protection.

At Bepto, we combine advanced manufacturing capabilities with comprehensive quality assurance to deliver A2 type brass cable glands that exceed industry standards. Our commitment to construction excellence and customer satisfaction drives continuous improvement in design and manufacturing processes 😉

FAQs About A2 Type Brass Cable Gland Construction

Q: What is the difference between A2 type and standard brass cable glands?

A: A2 type cable glands feature enhanced construction with thicker body walls (2.5-4.0mm vs 1.5-2.5mm), extended thread engagement, integrated armor clamping systems, and dual sealing mechanisms for superior performance in heavy-duty applications.

Q: How long do A2 type brass cable glands typically last?

A: A2 type brass cable glands are designed for 20+ years service life under normal conditions, with 15+ years in harsh environments, depending on installation quality, environmental conditions, and maintenance practices.

Q: Can A2 type cable glands be used with non-armored cables?

A: Yes, A2 type cable glands can accommodate both armored and non-armored cables, though they are specifically optimized for armored cable applications with integrated armor clamping and earthing features.

Q: What torque specifications should be used for A2 type cable gland installation?

A: Torque specifications vary by size, typically ranging from 15-25 Nm for M12-M20 sizes up to 80-120 Nm for larger sizes. Always follow manufacturer specifications to ensure proper sealing without component damage.

Q: Are A2 type brass cable glands suitable for marine applications?

A: Yes, A2 type brass cable glands with appropriate surface treatments (nickel plating) and marine-grade sealing materials provide excellent performance in marine environments, meeting IP68 protection requirements for saltwater exposure.

  1. Understand the concept of earthing continuity and its importance for electrical safety and protection.

  2. View the technical specifications, composition, and properties for the CW617N brass alloy.

  3. Explore the thread rolling manufacturing process and its benefits for fastener strength and durability.

관련

사무엘 벱토

안녕하세요, 저는 케이블 글랜드 업계에서 15년 경력을 쌓은 선임 전문가 사무엘입니다. 벱토에서 저는 고객에게 고품질의 맞춤형 케이블 글랜드 솔루션을 제공하는 데 주력하고 있습니다. 저는 산업용 케이블 관리, 케이블 글랜드 시스템 설계 및 통합, 주요 구성 요소 적용 및 최적화에 대한 전문 지식을 보유하고 있습니다. 궁금한 점이 있거나 프로젝트 요구 사항에 대해 논의하고 싶으시면 언제든지 다음 연락처로 문의해 주세요. gland@bepto.com.

목차
연락처 양식
벱토 로고

정보 양식 제출 후 더 많은 혜택 받기

연락처 양식